Value of serial peak expiratory flow measurements in assessing treatment response in chronic airflow limitation.

A double blind, randomised, placebo controlled, crossover trial of prednisolone (40 mg/day for 14 days) was carried out in 33 patients with chronic airflow limitation (mean age 62 years, mean FEV1 1.01 litres, mean FEV1/FVC ratio 44%), to assess the value of serial peak expiratory flow (PEF) measure...